background image

GC6057

DISASSEMBLY & REASSEMBLY ADVICE - STAND

SAFETY CAP 21

COMPLETE TRAY  22

Note: pressure fi xation rubber 

through the tray.

SUPERIOR STAND

PRINTED 29)

Remove 

screws A (4x)

A 4x

Remove the SUPERIOR STAND and 
you will see the respective parts of the 
Boiler.

REPAIR INSTRUCTIONS - STAND

-  For disassembly, you will need a Torx screwdriver 362 TR T20 x 100
-  Be careful of the sharp edges of the stainless steel tray assy. a 

thick glove

 when 

removing the tray assy.

-  To avoid damage to the sealings and components of the boiler, 

NEVER

 clean the 

boiler with vinegar, descaling agent or other chemicals.

-  The boiler does not contain serviceable parts. Never disassemble and service any 

components on the boiler assy.

-  The boiler is required to be rinsed after every 10 times usage.

ALWAYS

 replaced boiler assy (Pos 26) when

•  mechanical safety valve at the cap has been activated
•  thermal fuse/thermostat at boiler bottom is open

4-5

Summary of Contents for Provapor Elance GC6057

Page 1: ...fety Information This product meets the requirements regarding interference suppression on radio and TV After the product has been repaired it should function properly and has to meet the safety requirements as officially laid down at this moment TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power consumption Iron 800 W Boiler 1200 W Pressure 2 0 bar Dimension F box 41 x 38 x 20 cm We...

Page 2: ...CE INTERMEDIATE CABLE 7 SWIVEL 8 THERMOSTAT BUSH 9 disassemble DIAL 1 remove screw A remove connection remove hose disassemble BACKPLATE 2 disassemble INLAY 3 IRON LAMP 4 MICRO SWITCH 5 remove screw B 3x disassemble IRON HANDLE 6 REPLACE IRON SKIRT 10 SOLEPLATE UNIT 11 disassemble DIAL 1 remove screw A remove connection remove hose disassemble BACKPLATE 2 disassemble INLAY 3 IRON LAMP 4 MICRO SWIT...

Page 3: ... 12 4239 021 20720 4239 026 16310 4239 026 16320 4239 017 08940 4239 017 08950 4239 021 20730 4239 021 20700 4239 026 15580 4239 015 98410 4239 026 16340 4239 021 20710 4239 026 16350 Dial Backplate Inlay Iron Lamp Micro switch Iron Handle Intermediate cable micro switch Swivel Thermostat bush Iron skirt Soleplate unit Electrovalve trigger ...

Page 4: ...ful of the sharp edges of the stainless steel tray assy a thick glove when removing the tray assy To avoid damage to the sealings and components of the boiler NEVER clean the boiler with vinegar descaling agent or other chemicals The boiler does not contain serviceable parts Never disassemble and service any components on the boiler assy The boiler is required to be rinsed after every 10 times usa...

Page 5: ...09260 4239 021 19990 Safety cap Complete tray Tray rubber foot Boiler rubber foot Intermediate supply cable Europe Intermediate supply cable Italy Boiler assy Pos Service code Description 27 28 29 30 31 32 38 4239 010 08870 4239 017 08810 4239 021 20280 4239 026 16030 4239 015 55350 4239 015 55300 4239 017 09151 Electrovalve Main switch Superior stand Inferior stand Back support rubber Filling hol...