background image

8

en | Safety

Power Supply

AR18-10-B002 | v1.1 | 2011.10

Installation manual

Bosch Security Systems

1.3

Important Notices

All-pole power switch - 

Incorporate an all-pole power switch, 

with a contact separation of at least 3 mm in each pole, into the 

electrical installation. If it is needed to open the housing for 

servicing and/or other activities, use this all-pole switch as the 

main disconnect device for switching off the voltage to the unit.

Environmental statement - 

Bosch has a strong commitment 

towards the environment. This unit has been designed to 

respect the environment as much as possible.

Fuse rating - 

For protection of the device, the branch circuit 

protection must be secured with a maximum fuse rating of 16A. 

This must be in accordance with 

NEC800 (CEC Section 60)

.

Grounding and polarization - 

This unit may be equipped with a 

polarized alternating current line plug (a plug with one blade 

wider than the other blade). This safety feature allows the plug 

to fit into the power outlet in only one way. If unable to insert 

the plug fully into the outlet, contact a locally certified 

electrician to replace the obsolete outlet. Do not defeat the 

safety purpose of the polarized plug.

Alternately, this unit may be equipped with a 3-pole grounding 

plug (a plug with a third pin for earth grounding). This safety 

feature allows the plug to fit into a grounded power outlet only. 

If unable to insert the plug into the outlet, contact a locally 

certified electrician to replace the obsolete outlet. Do not 

defeat the safety purpose of the grounding plug.

Moving - 

Disconnect the power before moving the unit. Move 

the unit with care. Excessive force or shock may damage the 

unit.

Outdoor signals -

 The installation for outdoor signals, especially 

regarding clearance from power and lightning conductors and 

transient protection, must be in accordance with 

NEC725

 and 

NEC800 (CEC Rule 16-224

 and 

CEC Section 60)

.

Permanently connected equipment - 

Incorporate a readily 

accessible disconnect device external to the equipment.

Pluggable equipment - 

Install the socket outlet near the 

equipment so it is easily accessible.

Summary of Contents for PSU-124-DC050

Page 1: ...Power Supply PSU 124 DC050 en Installation manual ...

Page 2: ......

Page 3: ... 4 1 2 Important safety instructions 5 1 3 Important Notices 8 1 4 FCC ICES compliance 9 1 5 UL certification 11 1 6 Bosch notices 12 2 Installation 13 2 1 Tools required 13 2 2 Opening the side covers 13 2 3 Mount the unit 13 2 4 Connecting the input cable 14 2 5 Connecting the output cables 15 3 Technical Data 16 3 1 Specifications 16 3 1 1 Dimensions 17 ...

Page 4: ...ch as Dangerous Voltage inside the product If not avoided this will result in an electrical shock serious bodily injury or death WARNING Medium risk Indicates a potentially hazardous situation If not avoided this could result in minor or moderate bodily injury CAUTION Low risk Indicates a potentially hazardous situation If not avoided this could result in property damage or risk of damage to the u...

Page 5: ... operation Do not block or cover these openings Do not place the unit in an enclosure unless proper ventilation is provided or the manufacturer s instructions have been adhered to 4 Object and liquid entry Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electrical shock Never spill liquid of...

Page 6: ...rate the unit only from the type of power source indicated on the label Before proceeding be sure to disconnect the power from the cable to be installed into the unit For battery powered units refer to the operating instructions For external power supplied units use only the recommended or approved power supplies For limited power source units this power source must comply with EN60950 Substitutio...

Page 7: ... follows the operating instructions 13 Replacement parts Be sure the service technician uses replacement parts specified by the manufacturer or that have the same characteristics as the original parts Unauthorized substitutions may cause fire electrical shock or other hazards 14 Safety check Safety checks should be performed upon completion of service or repairs to the unit to ensure proper operat...

Page 8: ...ws the plug to fit into the power outlet in only one way If unable to insert the plug fully into the outlet contact a locally certified electrician to replace the obsolete outlet Do not defeat the safety purpose of the polarized plug Alternately this unit may be equipped with a 3 pole grounding plug a plug with a third pin for earth grounding This safety feature allows the plug to fit into a groun...

Page 9: ...ermined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and receiver connect the equipment into an outlet on a circuit different from that to which the receiver is connected consult the dealer or an experienced radio TV tech...

Page 10: ...n particulière Il est possible de déterminer la production d interférences en mettant l appareil successivement hors et sous tension tout en contrôlant la réception radio ou télévision L utilisateur peut parvenir à éliminer les interférences éventuelles en prenant une ou plusieurs des mesures suivantes Modifier l orientation ou l emplacement de l antenne réceptrice Éloigner l appareil du récepteur...

Page 11: ...ling aspects of this product UL MAKES NO REPRESENTATIONS WARRANTIES OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING RELATED FUNCTIONS OF THIS PRODUCT Disclaimer Underwriter Laboratories Inc UL has not tested the performance or reliability of the security or signaling aspects of this product UL has only tested fire shock and or casualty hazards as ...

Page 12: ...ithout notice Bosch Security Systems accepts no liability for damage resulting directly or indirectly from faults incompleteness or discrepancies between the user guide and the product described More information For more information please contact the nearest Bosch Security Systems location or visit www boschsecurity com Disposal Your Bosch product was developed and manufactured with high quality ...

Page 13: ...ing side covers Unscrew the four cross head screws at each corner and remove each of the side covers 2 3 Mount the unit Figure 2 2 Mounting the unit Secure the unit to a flat surface using mounting screws not supplied in the four holes 4 mm shown in the figure CAUTION Installation should only be performed by qualified service personnel in accordance with the National Electrical Code or applicable ...

Page 14: ... the input cable through the supplied grommet For each wire push back the tab behind the terminal with a small screwdriver and insert the wire respect the polarity shown in the figure release the tab to clamp the wire in place Secure the grommet firmly Return the protective cover to its position and fasten in place with the four cross head screws Note Tighten screws firmly to ensure protection aga...

Page 15: ...pproximately 5 mm 0 2 in Pass the output cables through the supplied grommets For each wire push back the tab behind the terminal with a small screwdriver and insert the wire respect the polarity shown in the figure release the tab to clamp the wire in place Secure the grommets firmly Return the protective cover to its position and fasten in place with the four cross head screws Note Tighten screw...

Page 16: ...C Frequency range 50 to 60 Hz AC current 0 9 A 115 VAC 0 2 A 230 VAC Construction Weight 850 g Material Casing Aluminum extrusion End caps mild steel Finish Powder coated paint RAL 9010 Pure White Cable glands Suitable for cable diameter 4 to 8 mm Environment Water protection IP66 Working temperature 30 to 50 C 22 to 122 F Working humidity 20 to 95 RH non condensing Storage temperature 40 to 80 C ...

Page 17: ...3 1 Dimensions Safety EMC Safety standards EN60950 1UL60950 1EN60950 22 IP66 Harmonic current Compliance to Class C less than 75 load EN61000 3 3 EMS immunity Compliance to EN61000 4 2 3 4 5 6 8 11 ENV50204 EN55024 EN61547 light industry level surge 4KV criteria A 47 1 85 123 4 84 mm in 81 3 17 150 5 9 195 7 68 101 3 98 91 3 57 ...

Page 18: ...18 en Technical Data Power Supply AR18 10 B002 v1 1 2011 10 Installation manual Bosch Security Systems ...

Page 19: ......

Page 20: ...Bosch Security Systems Inc 850 Greenfield Road Lancaster PA 17601 USA www boschsecurity com Bosch Security Systems Inc 2011 ...

Reviews: