20
| English
1 609 92A 1C8 | (24.6.15)
Bosch Power Tools
Noise/Vibration Information
The vibration level given in this information sheet has been
measured in accordance with a standardised test given in
EN 60745 and may be used to compare one tool with anoth-
er. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main ap-
plications of the tool. However if the tool is used for different
applications, with different accessories or insertion tools or is
poorly maintained, the vibration emission may differ. This
may significantly increase the exposure level over the total
working period.
An estimation of the level of exposure to vibration should also
take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may sig-
nificantly reduce the exposure level over the total working
period.
Identify additional safety measures to protect the operator
from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work pat-
terns.
Declaration of Conformity
We declare under our sole responsibility that the product de-
scribed under “Technical Data” is in conformity with all rele-
vant provisions of the directives 2011/65/EU, until
19 April 2016: 2004/108/EC, from 20 April 2016 on:
2014/30/EU, 2006/42/EC including their amendments and
complies with the following standards: EN 60745-1,
EN 60745-2-3.
Technical file (2006/42/EC) at:
Robert Bosch GmbH, PT/ETM9,
70764 Leinfelden-Echterdingen, GERMANY
Robert Bosch GmbH, Power Tools Division
70764 Leinfelden-Echterdingen, GERMANY
Leinfelden, 24.06.2015
Assembly
Mounting the Protective Devices
Before any work on the machine itself, pull the mains
plug.
Note:
After breakage of the grinding disc during operation or
damage to the holding fixtures on the protection guard/power
tool, the machine must promptly be sent to an after-sales
service agent for maintenance. For addresses, see section
“After-sales Service and Application Service”.
Restarting Protection
Overload Protection
–
Weight according to EPTA-Procedure 01:2014
– with vibration-damping auxiliary handle
– with standard-auxiliary handle
kg
kg
2.2
2.2
2.1
2.1
2.4
2.4
Protection class
/
II
/
II
/
II
Sound emission values determined according
to EN 60745-2-3.
PWS ...
1000-125
1000-125 CE
1300-125 CE
3 603 ...
CA2 6..
CA2 8..
CA2 9..
Typically the A-weighted noise levels of the
product are
Sound pressure level
Sound power level
Uncertainty K
Wear hearing protection!
dB(A)
dB(A)
dB
90
100
3
90
101
3
93
104
3
Vibration total values a
h
(triax vector sum) and
uncertainty K determined according to
EN 60745-2-3:
Surface grinding:
a
h
K
Disk sanding:
a
h
K
m/s
2
m/s
2
m/s
2
m/s
2
7.0
1.5
5.0
1.5
8.0
1.5
5.0
1.5
13.0
1.5
6.0
1.5
Angle Grinder
PWS ...
1000-125
1000-125 CE
1300-125 CE
The values given are valid for a nominal voltage [U] of 230 V. For different voltages and models for specific countries, these values can vary.
Henk Becker
Executive Vice President
Engineering
Helmut Heinzelmann
Head of Product Certification
PT/ETM9
OBJ_BUCH-1961-006.book Page 20 Wednesday, June 24, 2015 9:26 AM