background image

10�2 

Possible errors and their correction

The following table shows possible errors and their correction.

Error number

Error description

Error correction

"Err 110"

Data storage error  

Switch the device off and on again. If the error occurs again, return 
the device for repair.

"Err 210/220"

Sensor error (occurs only with 
absolute measuring systems).

Switch the device off and on again. If the error occurs again, check 
the measuring system and its wiring. If unsuccessful, return the 
device for repair.

"Err 240"

Power supply breaks down 
during operation.

Switch the device off and on again. If the error occurs again, check 
the supply source or the power pack. If unsuccessful, return the 
device for repair.

"Err 250"

Power supply breaks down 
during switch-on.

Switch the device off and on again. If the error occurs again, check 
the supply source or the power pack. If unsuccessful, return the 
device for repair.

10�3 

Recommissioning after fault clearance

After eliminating the fault(s):

If necessary, reset the emergency stop device

If necessary, reset the error message at the superior system

Make sure that there are no persons in the danger zone

Follow the instructions in section 5

WARNING!
Risk of injury due to improper fault clearance!

Improper fault clearance can lead to severe personal injuries or damage of property. 

Therefore:

 

Any work to eliminate faults may only be performed by sufficiently qualified and instructed 

personnel.

 

Before starting work, ensure that there is sufficient installation space.

 

Make sure that the installation site is tidy and clean. Loose components and parts lying 

around or on top of each other are sources of accidents. 

If components need to be replaced:

 

Pay attention to correct installation of the spare parts.

 

Reinstall all fixing elements properly.

 

Before recommissioning, make sure that all covers and safety equipment are installed 

correctly and function properly.

10�4 

Maintenance

The device is maintenance-free.

10�5 

Cleaning

WARNING!

The device must only be cleaned with a damp cloth. Do not use aggressive detergents!

Table 6: 

Error messages and their correction

R320103179/2019-12

 

| IMScompact position display  

Bosch Rexroth AG 

15/18

Summary of Contents for R168393000

Page 1: ...103179 2019 12 EN Position display with signal input for 1 axis Input for IMScompact TTL Adjustable reference value tool offset and saw blade thickness 7 digit LCD display including sign and measuring units 2 configurable digital control inputs Data memory in case of power failure ...

Page 2: ...o describe the product No statements concerning a certain condition or suitability for a certain purpose can be derived from our information The information given does not release the user from the obligation of own judgment and verification It should be noted that our products are subject to a natural process of aging and wear Bosch Rexroth AG All rights reserved including the right to apply for ...

Page 3: ...nd damage to property Warnings DANGER This symbol in connection with the signal word Danger indicates an imminent danger to the life and health of persons Failure to observe these instructions will result in serious damage to health or even life threatening injuries WARNING This symbol in connection with the signal word Warning indicates a possible danger to the life and health of persons Failure ...

Page 4: ...ing the device Notes on installation must be observed Only commission the device if you have understood the operating instructions The operator must take and implement appropriate security relevant measures Commissioning must only be performed by qualified personnel authorized and instructed by the operator 2 5 General sources of danger This section provides an overview of important safety issues ...

Page 5: ... and loading CAUTION Transport the packaging box pallet etc professionally Do not throw hit or fold it 2 9 Handling of packaging material Notes for proper disposal 2 4 2 10 Inspection of transport Check the delivery immediately upon receipt for completeness and transport damage In case of externally recognizable transport damage Do not accept the delivery or only under reserve Note the extent of d...

Page 6: ...h signal input for 1 axis Input for conventional encoders and measuring systems Adjustable reference value tool offset and saw blade thickness 7 digit LCD display including sign and measuring units Encoder supply 24 V DC Easy assembly Switching between relative and absolute dimension on the front panel Data storage in case of power failure 1 2 and 4 fold edge triggering Further information on thes...

Page 7: ...cy 1 digit Operating temperature 0 50 C Storage temperature 20 80 C Humidity max 80 non condensing Inputs max input current 10 mA PNP active high switching voltage 24 V DC Input frequency max 80 kHz Power down memory FRAM Housing Standard panel housing ABS plastic black Housing dimensions W x H 72 x 48 mm Installation depth 27 mm without connection plug Panel cutout W x H 68 x 45 mm Protection typ...

Page 8: ...se to interference sources which have strong inductive or capacitive interference or strong electrostatic fields CAUTION Electrical connections must be made by appropriately qualified personnel in accordance with local regulations The device may be designed for switchboard mounting During work on the switchboard all components must be de energized if there is a danger of touching energized parts P...

Page 9: ... characteristics of the input is 24 V DC PNP which means that the input is active at a high level The function of input 1 can be programed by using parameter P17 connector S1 5 9 The function of input 2 can be programed by using parameter P18 connector S1 6 9 see parameter description 7 6 2 Encoder supply For the measuring system or encoder supply a 24 V DC supply is available at the terminals or ...

Page 10: ...t to 0 in absolute mode Press for 3 seconds change tool offset Return to regular mode with the Incr Abs key F Incr Abs Press for 3 seconds call up the parameter level Parameter level Press shortly select decade Press shortly increase decade Incr Abs Press shortly save changes and switch over to next parameter F Entry of negative parameters negative sign only possible if value is unequal to 0 F Inc...

Page 11: ...nge 000000 1 999999 9 P11 Saw blade Adjustment of the saw blade thickness Range 0000 1 9999 9 P16 Default initialization Reset to factory parameters 0 not init 1 default init Enter 1 in this parameter and confirm with the Incr Abs key Then switch off the device After switching the device on again the factory parameters have been uploaded and the device has been reset P17 Function of external input...

Page 12: ... 0 P08 Multiplication factor 01 00000 01 00000 P09 Reference value 000000 0 P10 Tool offset 000000 0 P11 Saw blade 0000 0 P12 Reserve P13 Reserve P14 Reserve P15 Reserve P16 Default init 0 not active P17 Function ext input 1 0 not active P18 Function ext input 2 0 not active P19 Trigger external input 1 0 level sensitive P20 Display mode 0 standard 0 P21 Reserve P22 Reserve P23 Reserve P24 Reserve...

Page 13: ...TL channel B 5 External input 1 24 V PNP 6 External input 2 24 V PNP 7 0 V GND power supply input 8 24 V DC power supply input Connector S2 9 pin D SUB female connector 5 V TTL inputs Terminal assignment for single wires to D SUB Breakout Box Pin Function Wire color Klemme 1 0 V GND encoder supply output Blue 1 2 24 V DC encoder supply output Red 2 3 TTL channel A 5 V level only Green 3 4 TTL chan...

Page 14: ...ide The figure shows how the shield is connected to the position display in order to avoid interferences The shields should not be grounded on both sides Signal cables should always be laid separately from load power lines A safety distance of at least 0 5 mm from inductive and capacitive interference sources such as contactors relays motors switching power supplies or clocked controllers has to b...

Page 15: ...y reset the emergency stop device 2 If necessary reset the error message at the superior system 3 Make sure that there are no persons in the danger zone 4 Follow the instructions in section 5 WARNING Risk of injury due to improper fault clearance Improper fault clearance can lead to severe personal injuries or damage of property Therefore Any work to eliminate faults may only be performed by suffi...

Page 16: ...3 S N 2598783 TYP DIGITAL DISPLAY TTL FD 211 4 5 6 1 2 3 7 1 Material number 2 Serial number 3 Type designation 4 CE mark 5 RoHS 6 Department factory number 7 Company address Fig 5 Type designation 16 18 Bosch Rexroth AG IMScompact position display R320103179 2019 12 ...

Page 17: ...R320103179 2019 12 IMScompact position display Bosch Rexroth AG 17 18 ...

Page 18: ...le as a PDF R320103179 2019 12 Subject to technical modifications Bosch Rexroth AG Ernst Sachs Straße 100 97424 Schweinfurt Germany Phone 49 9721 937 0 www boschrexroth com Find your local contact person here www boschrexroth com contact ...

Reviews: