SAC_PAR_QUADRATURE_SINGLE_ENDED. See the NYCe 4000
Tools Manual and the NYCe 4000 Software User Manual for more
information. If single-ended is selected via the parameter, the cable
break detection is disabled in software, and the cable alarm will never
occur.
T
ph
QuadA
QuadB
phase alarm if T
ph
< 16 ns
index
T
index
minimum pulse width index pulse T
index
= 25 ns
Cable break detection and maximum shift
T
skew
maximum allowed signal skew between balanced
inputs for proper cable break detection T
skew
< 2500 ns
input
inputN
Fig. 13-7:
Timing requirements of the encoder signals QuadA, QuadB and In‐
dex
Encoder inputs assignment
Backplane pin
Description
Remark
Enc#QuadA–, Enc#QuadA+
QuadA signal for axis#
1
Enc#QuadB–, Enc#QuadB+
QuadB signal for axis#
1
Enc#Index–, Enc#Index+
Index signal for axis#
2
Enc5V#
Power supply for axis#
1
EncVref
Common reference signal
-
EncGND
Common ground signals
-
1
# ■ 0, 1 for NY4120 and NY4130, 0 for NY4140, 0, 1, 2, 3, 4 for
NY4125
2
# ■ 0, 1 for NY4120 and NY4130, 0 for NY4140
Tab. 13-8:
Encoder inputs assignment
168/233
Encoders
NYCe 4000 Multi-axis motion control system Hardware Sys‐
tem Manual
Bosch Rexroth AG R911337671_Edition 18