-27-
Now check the position of the laser beam at a
reference point and, if necessary, correct the
height or alignment of the laser level.
Switching off the shock-warning function:
On the home screen, the current setting is
shown with the shock-warning indicator (c):
Shock-warning function is switched
on.
Shock-warning function is switched
off.
To switch the shock-
warning function off or
on, briefly press the
on/off button (11).
Then press the on/off button (11) in the menu
which appears as often as needed until the
required setting has been selected. Confirm
your selection with by pressing the slope
button (14).
If the shock-warning function has been
switched on, it will be activated after approxi-
mately 30 seconds.
Slope operation in the horizontal position
In the laser level’s horizontal position, the X-
axis and the Y-axis can be tilted independently
of each other in a range of ±8.5%.
To tilt the X-axis, press
the slope button (14)
on the measuring tool
or the slope button
(32) on the remote control once. The menu
for setting the slope of the X-axis will appear.
Set the required slope by using the buttons ▲
(4) or ▼ (3) on the measuring tool or using the
up (31) or down (36) slope buttons on the re-
mote control. Pressing both slope buttons on
the measuring tool or on the remote control at
the same time resets the slope back to 0.00%.
To tilt the Y-axis, press
the slope button (14)
on the measuring tool
or the slope button
(32) on the remote control again. The menu
for setting the slope of the Y-axis will appear.
Set the required slope in the same way as out-
lined for the X-axis.
The required slope is implemented
on the measuring tool a few sec-
onds after the last press of a but-
ton. The laser beam and the symbol
for setting the slope will flash on the display
until the process of setting the slope has been
completed.
After the process of
setting the slope has
been completed, the
set slope values of
both axes will be shown on the start screen.
The status indicator (12) on the measuring
tool will light up red continuously. The status
indicator for the tilted axes ((35) and/or (34))
will light up red continuously.
Manual operation
The automatic leveling of the laser level can
be switched off (manual operation):
– in the horizontal position for both axes in-
dependently of each other,
– in the vertical position for the X-axis (the
Y-axis cannot be levelled in the vertical po-
sition).
It is possible to set up the laser level at any
inclination in the manual operation mode. The
axes can also be tilted independently of each
other in a range of ±8.5% on the laser level. In
manual operating mode, the slope value of an
axis will not be shown on the display.
The status indicator (12) on the laser level will
light up red continuously if:
– at least one axis is set to manual operating
mode in the horizontal position,
– the X-axis is set to manual operating mode
in the vertical position.
The Y-axis status display (35) or the X-axis sta-
tus display (34) on the remote control light up
red continuously if the relevant axis is set to
manual operating mode.
Manual operation cannot be started via re-
mote control. However, you can change the
slope of an axis in exactly the same way us-
ing the Slope button up (31) and the Slope
button down (36) on the remote control and
the buttons ▲ (4) and ▼ (3) on the measuring
tool.
Manual operation in the horizontal position
To switch off automat-
ic leveling, press the
manual operation but-
ton (13) until the re-
quired settings combination for both axes is
achieved. In the illustrated example, automat-
ic leveling for the X-axis is switched off and
the Y-axis continues to be leveled.