UDS-10 / UDS-1100 Serial Tunnel on CNC 

Setup Guide 

 

 

 

 

 

 

 

Summary of Contents for Readykey X UDS-10

Page 1: ...17553v1 0 Jan 08 UDS 10 UDS 1100 Serial Tunnel on CNC Setup Guide ...

Page 2: ...tion 4 3 1 DeviceInstaller Configuration 4 3 2 Telnet Configuration 7 3 2 1 Connecting to the UDS 7 3 2 2 UDS to PC Configuration 7 3 2 3 PC to Door Controller Configuration 9 3 3 Testing Network Connectivity 10 4 Configuring the Door Controller 11 5 Configuring the Channel 11 ...

Page 3: ...into packets and transports them over the network Note If replacing pIPer Serial Ethernet units the pIPers at both ends must be replaced with UDS devices 2 Installation UDS 1 is connected to a serial port on the PC CNC A standard 9 way to 25 way serial cable can be used UDS 2 is connected to the serial port on the first door controller The serial lead can be supplied part no 12090 Alternatively a ...

Page 4: ...guration Notes 1 The procedure carried out in this section has to be performed before Telnet Configuration see Section 3 2 can be carried out 2 Make a note of the MAC Address of the UDS printed on the underside of the UDS or on the cover above the IP unit of the K2200IP 3 Consult your IT department to determine the IP Address and the PC Network Class for the UDS Procedure 1 Run the DeviceInstaller...

Page 5: ...Search the network for devices and the Search Network window is displayed 7 Select the PC Network Class 8 Select the Start Search button and any UDS devices on the network will be displayed 9 Select the Save button and the DeviceInstaller window is redisplayed with a list of all UDS devices detected ...

Page 6: ...evice 11 Select Tools Device Manager and the Device Management window is displayed 12 Select Telnet to Device and a Telnet session will then start The DeviceInstaller part of the UDS configuration is complete the next part is using Telnet ...

Page 7: ... Software Version V04 2 000908 Press Enter to go into Setup Mode Press Enter Hardware Ethernet Autodetect IP addr 192 168 31 202 no gateway set netmask 255 255 255 000 Security Telnet setup is enabled TFTP download is enabled Port 77FEh is enabled Web Server is enabled Enhanced password is disabled Channel 1 Baudrate 9600 I F Mode 4C Flow 00 Port 10001 Datagram Type 01 Pack Cntrl 00 Remote IP Adr ...

Page 8: ...r other examples Mask Bits 255 0 0 0 24 255 255 0 0 16 255 255 240 0 12 255 255 248 0 11 255 255 254 0 9 255 255 255 0 8 255 255 255 128 7 255 255 255 192 6 255 255 255 224 5 255 255 255 240 4 255 255 255 248 3 Change telnet config password Press the N key and press Enter The basic parameters menu will be displayed basic parameters Hardware Ethernet Autodetect IP addr 192 168 004 241 no gateway se...

Page 9: ...efault value I F Mode Press Enter to accept the default value Flow Press Enter to accept the default value Port No Enter the port number and press Enter ConnectMode Enter the connect mode for the administration software and press Enter Datagram Type Enter the value 01 and press Enter Remote IP Address Enter IP address of the PC and press Enter Remote Port Press Enter to accept the default value Pa...

Page 10: ...ing Device and the Ping Device window is displayed 3 Enter the IP Address of the unit to be pinged and select the Ping Device Successful pinging will be indicated by text similar to that displayed Note Do not attempt to set up the door controller within application software until you have established that the PC can see the UDS over the network ...

Page 11: ...1 System Type 2 2 Baud Rate to 9600 3 Connect Modem set to N To set these parameters see the documentation supplied with the door controller 5 Configuring the Channel The channel can be configured using Readykey for Windows or Readykey X To set up the channel see the documentation and helpfiles supplied with the application software ...

Page 12: ...www boschsecurity us ...