▶ Ensure that no other device in the area, such as a cordless 

phone, is operating on a frequency similar to the remote 
(915 MHz) and causing interference.

▶ Double check all wire connections made under section

 

4.1 

or section 5.1 of the remote control manual. Pay close 
attention to the wire connecting the remote's PCB to the 
heater's main PCB.

3. 

Remote display shows “- -” only

▶ Verify the water heater's ON/OFF switch is turned to the ON 

(I) position. If the water heater's display is still blank, verify 
the heater is plugged into a live 120VAC/ 60Hz properly 
grounded outlet.

▶ Verify there is proper voltage to the water heater (120VAC/

60Htz).

▶ Verify the remote is within the maximum distance from the 

water heater of 98 feet.

▶ Ensure that no other device in the area, such as a cordless 

phone, is operating on a frequency similar to the remote 
(915 MHz) and causing interference

Large amounts of metal or concrete in the 
structure may have a blocking effect on the 
remote's signal. This may alter the maximum 
distance allowable from the water heater.
▶ Move within direct line of sight of the water 

heater to see if signal will reconnect.

4. Error code and “

” symbol will not clear from remote

Error codes cannot be reset by using the remote. All errors 
must be cleared by using the reset button 

 on the 

water heater's control panel

If an error code is generated immediately after the 
installation of the remote control transceiver PCB, ensure 
that the electrical connectors (Fig. 10) on the main PCB are 
properly seated.

Error code may not be resettable. Consult water heater's 
installation manual or www.boschpro.com for further 
troubleshooting on error codes

5. Remote will not memorize desired temperature 

setting

▶ Verify that the remote control “program” button is 

depressed until the remote display reads “Pr”.

Memorization of a selected temperature only 
saves to the device on which it was originally 
programmed. To retrieve a memorized 
temperature setting, you must use the device 
with which it was programmed.

6. Priority "

" symbol will not clear

▶ Verify no hot water is being used when trying to clear 

"priority" function.

▶ With no hot water running, press and hold the “

” or 

” buttons for 5 seconds on the locked out device 

(remote or water heater) until the "

" symbol (Fig. 11, 

[6]) disappears.

▶ Do not use any hot water for at least 5 minutes. The priority 

function should automatically clear after this time period.

8

Environment / disposal

Environmental protection is a fundamental corporate strategy 
of the Bosch Group.  
The quality of our products, their efficiency and environmental 
safety are all of equal importance to us and all environmental 
protection legislation and regulations are strictly observed. 
We use the best possible technology and materials for 
protecting the environment taking into account of economic 
considerations.

Packaging

We participate in the recycling programmes of the countries in 
which our products are sold to ensure optimum recycling.  
All of our packaging materials are environmentally friendly and 
can be recycled.

Old electrical and electronic appliances

Electrical or electronic devices that are no 
longer serviceable must be collected 
separately and sent for environmentally 
compatible recycling (in accordance with the 
European Waste Electrical and Electronic 
Equipment Directive).

To dispose of old electrical or electronic 
devices, you should use the return and 
collection systems put in place in the country 
concerned.

Summary of Contents for Remote Control

Page 1: ...635 ESO 250SX 250SXO 2400E 2400EO 2400ES 2700ES 715ES C800ES C920ES C920ESC EVOLUTION 500 INTEGRA 500 C1210ES C1210ESC C1050ES C950ES 940ES 940ESO 830ES Bosch Remote Control 6720606990 00 1JS 6 720 606 990 2014 06 US ...

Page 2: ...emote control installation for GWHC920ES GWH C920ESC GWH C800 ES GWH 715 ES GWH 2700 ES GWH2400ES EVOLUTION500 INTEGRA500 C1210ES C1210ESC C1050ES C950ES 940ES 940ESO 830ES 7 5 1 Remote control transceiver PCB installation 7 5 2 Remote control activation 8 6 Remote control 8 6 1 Description of the LCD 8 6 2 Hot water temperature adjustment by remote control 9 6 3 Program button on the remote contr...

Page 3: ...ollowingcountries UnitedStates of America and Canada This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 2 Remote control data Remote control for temperature adjustment of Bosch water h...

Page 4: ...ycover Fig 4 seediagrambelow andthenloosen the 110V power supply cord retaining nut located underneaththeheater Onceloosened thepowercordcan be pulled up through the heater to provide sufficient slack Once auxiliary cover isoff pulloffthetwo electrical strip con nectors from the board Once off the wiring harness can beremovedfromthe case by pulling their rubber seals out ward Fig 3 Electrical stri...

Page 5: ...ctions vary based on the version of control board installed in your heater Todeterminethecontrolboardversioninthewaterheater Turn power switch on the water heater to the off position O Whenturningpowerswitchtotheonposition notethefirst twolettersthatappearonthedisplay shouldbeAForSU If the letters are AF follow section 4 2 1 For SU follow section 4 2 2 4 2 1 AF board Connect power to heater Move t...

Page 6: ...d the first remote control will be registered with number 0 the second with number 1 and so on The rotating digit shows that the electronics is expecting a registration If the LCD fails to show a number and rotating digit after repeatedattempts doublecheckthewireconnectionsmadein section 4 1 Hold remote control in front of the control panel on the heater and simultaneously press remote control but...

Page 7: ...performing installation Pre installation preparation LoosenthetwoPhilipsheadscrewslocatedonbottomrear of cover Lift front cover upward and remove Remove the three screws from the control unit Fig 8 1 Fig 7 Remove the 6 screws from the back cover of the control unit to access the electronic board PCB Fig 8 2 6720606990 10 1AL Fig 8 Remote control transceiver PCB installation Place the remote contro...

Page 8: ...he rotating digit shows that the electronics is expecting a registration IftheLCDfailstoshowanumberandrotatingdigit after repeated attempts double check the wire connections made in section 5 1 Hold remote control in front of the control panel on the heater and simultaneously press remote control buttons and until the temperature indication is shown on the remote control LCD PressON OFFbuttononthe...

Page 9: ...e remote control Fig 13 3 for 3 seconds Note Previously saved temperature may show on the display when first pushing the program button Once PR shows on the display the desired setting will be saved Fig 13 Memorizing water temperature Only one temperature per remote control can be memorized using the Program button on the remote control At this point the remote control will display the memorized t...

Page 10: ...on the remote control display Use the hot water within two minutes of acquiring priority Priority cannot be acquired while the hot water tap is open 6 5 Error messages This device has an error message system Any errors that the heater generates will be indicated by an error code that will appear on the display Fig 11 1 and by a symbol indicating a safety block Fig 11 7 The remote control will be o...

Page 11: ...m for further troubleshooting on error codes 5 Remote will not memorize desired temperature setting Verify that the remote control program button is depressed until the remote display reads Pr Memorization of a selected temperature only saves to the device on which it was originally programmed To retrieve a memorized temperature setting you must use the device with which it was programmed 6 Priori...

Page 12: ......

Reviews: