Installation 35/60
RE 92801-01-B/11.2018, A15VSO/A15VLO Series 11,
Bosch Rexroth AG
5
3
4
4
1
2
or
X
(LRDRS0)
Fig. 13: Removing transport protection
1
Protective cover
2
Threaded plugs
3
Protective plug
4
Steel flange covers (the flange cover
on the suction port provides a secure
stand and protection for the V
g max
stop)
5
For version with through drive,
protective cover and mounting
bolts
Ports intended for connecting lines come with protective plugs or threaded plugs,
which serve as transport protection. Connect all ports required for functional
operation (see Table 12 "Ports A15VSO/A15VLO series 11" on page 39). Failure
to do so could lead to malfunctions or damage. If a port is not being used, it is to
be plugged with a threaded plug since the protective plugs are not pressure-resistant.
Important for LRDRS0 controllers!
Port
X
is equipped with a protective plug (
3
).
This port must be connected. Failure to do so could lead to malfunctions
or damage.
You will find other ports for the respective control in the data sheet 92801.
Setting screws are protected against unauthorized adjustment by tamper-proof
caps. Removal of the tamper-proof caps will void the warranty. If you need
to change the settings, please contact your local contact person; you can find
their contact information at
www.boschrexroth.com/addresses