28/60 Installation
Bosch Rexroth AG
, A15VSO/A15VLO Series 11, RE 92801-01-B/11.2018
7.3 Installation position
The axial piston unit can be installed in the following positions. The pipeline routing
shown illustrates the basic layout.
7.3.1 Below-reservoir installation (standard)
Below-reservoir installation is when the axial piston unit is installed outside
of the reservoir below the minimum fluid level.
Recommended installation position: 1 and 2.
1
2
3
SB
h
t min
h
min
T
1
T
3
T
2
S
F
F
F
SB
h
t min
h
min
T
1
T
3
T
2
S
SB
h
t min
h
min
T
1
T
3
T
2
S
T
1
,
T
2
,
T
3
Highest drain port
SB
Baffle (baffle plate)
F
Filling/air bleeding
h
t min
Minimum required immersion depth
(200 mm)
S
Suction port
h
min
Minimum required distance
to reservoir bottom (100 mm)
Port
F
is part of the external piping and must be provided on the customer side
to make filling and air bleeding easier.
Table 9: Below-reservoir installation
Installation position
Air bleed
Filling
1 (drive shaft horizontal)
T
1
+
F
S
+
T
1
2 (drive shaft horizontal)
T
2
+
F
S
+
T
2
3 (drive shaft vertically up)
T
2
+
F
S
+
T
2
Fig. 9: Below-reservoir installation A15VSO/A15VLO with installation position 1–3