2.4
Personnel Qualification
For the purpose of this manual, means persons who are familiar with trans‐
porting, installing, mounting, commissioning and operating the components of
the electrical drive and control system and the associated hazards and have
an appropriate qualification for their job.
All persons working on, with or in the vicinity of an electrical system must be
informed of the relevant safety requirements, safety guidelines and internal
instructions (DIN EN 50110-1).
2.5
General Safety Instructions
Do not install or operate motors or components of the electric drive and con‐
trol system before you have not carefully read all delivered documents.
Please observe the particular applicable national, local and system-specific
regulations, the in the documentation and the warning and informative labels
on the motors.
Improper use of the motors and failure to follow the safety instructions in this
document may result in material damage, personal injury, electric shock or, in
extreme cases, to death!
For damage due to non-compliance with the safety instructions, Bosch
Rexroth does not assume any liability.
Applications for functional safety are only allowed if the motors have the SI
sign on the rating plate.
2.6
Product and Technology-dependent Safety Instructions
2.6.1
Protection against Electrical Voltage
Work required on the electric system may only be carried out by skilled elec‐
tricians. Tools for electricians (VDE tools) are absolutely necessary.
Prior to commencing the work:
1. Isolate.
2. Protect the system or plant against restart.
3. Ensure de-energization.
4. Ground and short-circuit.
5. Cover or shield any adjacent live parts.
After completion of the work, unmake the measures in reverse order.
During operation, dangerous voltages occur! Danger! Risk of injury due to
electric shock!
●
Before switching on, establish the fixed connection of the protective con‐
ductor to all electric components according to the interconnection dia‐
gram.
●
Operation, even for short-term measuring and testing purposes, is only
permitted with the protective conductor securely connected to the com‐
ponent points provided.
2.6.2
Protection against Mechanical Hazards
Dangerous movements! Danger to life, risk of injury, severe personal injury or
material damage!