Fig.4-3:
Component subject to protection
Degree of
protection
Remark
④
Fan connection
IP65
Motor Fan
IP54
Fan motor IP54
Fan grille IP24
Fig.4-4:
Definition of protection class areas on the motor
4.1.4
Output Shaft
Centering hole
Centering hole, acc. to DIN 332-2
2AD...
100 ... 104
132 ... 134
160 ... 225
DS M8
■
DS M16
■
DS M20
■
Fig.4-5:
Centering hole
Keyway (option)
Corresponding key, according to DIN 6885-A
(not in scope of delivery)
2AD...
100 ...
104
132 ...
134
160 ...
164
180 ...
184
200 ...
225
10×8×45
■
12×8×80
■
16×10×80
■
18×11×110
■
20x12x110
■
Fig.4-6:
Keys
4.1.5
Bearings
2AD motors are equipped with permanently greased ball bearings. You will
find detailed notes about available bearing variants and their bearing life‐
time , in dependence from the shaft and bearing load, indthe project planning
manual
Rexroth 2AD Asynchronous Motors.
DOK-MOTOR*-2AD********-IT01-EN-P
Rexroth 2AD Asynchronous Housing Motors
Bosch Rexroth AG
23/61
About this Product
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪