6.2.3
Power Connection via Terminal Box
Motor frame size
2AD...
Terminal box
Designation
U-V-W
Terminal range
[mm²]
∅PE
Connection thread
Cable gland
100 ... 104
RLK0003
WEF
1)
1.5 ... 16
RKS
2)
for M6 thread
See details in project
planning manual
Rexroth 2AD
130 ... 164
RLK0004
WEF
1.5 ... 35
RKS for M8 thread
180 ... 184
RLK0005
WEF
1.5 ... 50
RKS for M10 thread
200 ... 225
RLK0007
RKS for M12
thread
1.5 ... 70
RKS for M12 thread
1)
WEF = wire end ferrule
2)
RTE = ring terminal end
Fig.6-6:
Overview of motors with terminal box
●
Please observe the necessary power wire cross-section to
connect the respective motor in the project planning manual
Rexroth 2AD.
●
Use ready-made cables of Rexroth, see documentation
Rexroth Connection Cables IndraDrive and IndraDyn.
●
Cables are screwed to the terminal box via adapter plates
and, if necessary, thread reducing fittings. These compo‐
nents are included in the motor delivery. If necessary, how‐
ever, they can also be reordered separately.
Terminal box connection diagram
①
Holding Brake (Optional)
②
Spare temperature sensor (connect spare sensor lines only if neces‐
sary)
③
Shield connection by clamping the cables of the strain relief in the ca‐
ble gland
④
Connection designations on the Rexroth drive controller
Fig.6-7:
Connection scheme terminal box
Bosch Rexroth AG
DOK-MOTOR*-2AD********-IT01-EN-P
Rexroth 2AD Asynchronous Housing Motors
36/61
Assembly