Please observe the general safety instructions on the protection against haz‐
ardous movements
chapter 2.6.2 "Protection against Mechanical Hazards"
.
7.3
Operation
During operation, adhere to the ambient and operation conditions and techni‐
cal data specified in the project planning manual
Rexroth 2AD.
Checks during operation:
Pay attention to exceptional noise.
Pay attention to increased vibrations.
Check the motor and fan units for cleanliness.
Check the cooling water connections for tightness.
Check the monitoring devices and diagnostic / error messages of the con‐
trollers.
Decommission the drive when deviations from normal operation exist. For
chapter 12 "Troubleshooting" on page 53
Bosch Rexroth AG
DOK-MOTOR*-2AD********-IT01-EN-P
Rexroth 2AD Asynchronous Housing Motors
44/61
Commissioning and Operation
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com