Servicing and repair
49/64
RE 79039-01-B/01.2021, MOBILEX GFB 8000 series 40 general operating instructions,
Bosch Rexroth AG
10.3
Maintenance schedule planetary gearbox
The material number-specific operating instructions may include a maintenance
schedule which is different from the maintenance schedule in the general
operating instructions. The maintenance schedule in the material number-
specific operating instructions always applies.
Check whether there is a different maintenance schedule for your planetary
gearbox in the material number-specific operating instructions.
The maintenance schedule, shown in table 6 “Maintenance schedule planetary
gearbox” only applies for the planetary gearbox. Therefore observe not only
with the maintenance schedule of the planetary gearbox but also with the
maintenance schedule included in the machine/vehicle manufacturer's
operating instructions.
Table 6
Maintenance schedule planetary gearbox
Interval
Action
NOTE
After 150 motor
operating hours
Perform the first oil change.
refer to chapter 10.4.2
Daily
Perform noise test
refer to chapter 10.2.3
Weekly
Perform visual inspection
refer to chapter 10.2.1
Perform oil level check
refer to chapter 10.2.2
Monthly
Check that the planetary gearbox
mounting screws are tightly secured
If necessary, retighten
mounting screws
Every six months
With existing grease nipple Use
lithium multi-purpose grease L-
XBCHA3 (GB 7324-94) or FAG
Arcanol MULTI3 or Klüberplex BE 31-
222 to grease the lubricating point
(output shaft)
If the bearing of the output
shaft in the output shaft
housing is grease-
lubricated, there is at least
one grease nipple on the
output side that you
should use to relubricate
the bearing.
Every year, however not
later than after 1500
motor operating hours
Perform oil change.
refer to chapter 10.4.2
10.4
Maintenance
If used in accordance with the intended purpose, the planetary gearbox is low-
maintenance.
The service life of the planetary gearbox essentially depends on the quality of its
lubricating oil. We therefore recommend changing the lubricating oil at least once
a year or every 1,500 operating hours (whichever is earlier).