28/60 Installation
Bosch Rexroth AG, A10VOH Series 60, RE 92704-01-B/2020-01-21
7.3 Installation position
The following installation position are permissible. The pipeline routing shown
illustrates the basic layout. Further installation positions are available upon request.
Recommended installation position: 1 and 2.
The drain ports
L
1
and
L
2
are present by default. Depending on the installation
position, another drain port is required.
7.3.1 Below-reservoir installation (standard)
Below-reservoir installation means that the axial piston unit is installed outside of
the reservoir below the minimum fluid level.
h
t min
SB
F
h
min
S
L
2
L
1
L
2
L
1
S
SB
F
h
t min
h
min
1
2
Fig. 7: Below-reservoir installation A10VOH with installation positions 1–2
F
Filling/air bleeding
h
t min
Minimum required immersion depth
(200 mm)
L
1
,
L
2
Drain port
h
min
Minimum required distance to
reservoir bottom (100 mm)
S
Suction port
SB
Baffle (baffle plate)
Port
F
is part of the external piping and must be provided on the customer side
to make filling and air bleeding easier.
Table 8: Below-reservoir installation
Installation position
Air bleed
Filling
1 (drive shaft horizontal)
F
S
+
L
1
2 (drive shaft horizontal)
F
S
+
L
2