Installation 35/60
RE 92704-01-B/2020-01-21, A10VOH Series 60, Bosch Rexroth AG
7.4.8 Completion of assembly
1.
Remove any installed transport screws.
CAUTION!
Operation with protective plugs!
Operating the axial piston unit with protective plugs may result in injury or damage
to the axial piston unit.
▶
Before commissioning, remove all protective plugs and replace them
with suitable, pressure-resistant, metal threaded plugs or connect the
appropriate lines.
2.
Remove the transport protection.
The axial piston unit comes with protective covers (
) and protective
plugs (
) not pressure-resistant and have to be removed prior to
connection. Use a suitable tool for this to prevent damage to the sealing and
functional surfaces. If sealing or functional surfaces are damaged, contact your
Bosch Rexroth service partner or the service department of the manufacturer's
plant of the axial piston unit.
1
1
2
2
5
3
4
Fig. 12: Removing transport protection
1
Protective covers
2
Protective plugs/threaded plugs
3
Connector protective covers
4
For version with through drive, spacer
made of plastic (serves as transport
protection)
5
For version with through drive,
protective cover and mounting bolts
Ports intended for connecting lines come with protective plugs and/or threaded
plugs, which serve as transport protection. Connect all ports required for
functional operation (see Table 11 "Ports A10VOH series 60" on page 38).
Failure to do so could lead to malfunctions or damage. If a port is not being used,
plug it with a threaded plug since the protective plugs are not pressure-resistant.
Adjusting the setting screws will render the warranty void. If you need to change
the settings, please contact your local contact person; you can find their
contact information at
www.boschrexroth.com/addresses