38/60 Installation
Bosch Rexroth AG, A10VOH Series 60, RE 92704-01-B/2020-01-21
L
1
L
2
X
B
S
L
4
Fig. 13: Port overview A10VOH
Table 11: Ports A10VOH series 60
Ports
1)
p
max
[bar]
2)
State
3)
B
Working port (high-pressure series)
420
O
S
Suction port (standard pressure series)
5
O
L
1
Drain port
2
O
4)
L
2
Drain port
2
X
4)
L
4
5)
Drain port
2
X
4)
X
Pilot pressure
420
O
1)
The measuring system and thread size can be found in the installation drawing.
2)
Depending on the application, momentary pressure peaks can occur. Keep this in mind when
selecting measuring devices and fittings.
3)
O = Must be connected (comes plugged)
X = Plugged (in normal operation)
4)
Dependent on the installation position,
L
1
,
L
2
or
L
4
must be connected (see chapter 7.3
"Installation position" on page 28).
5)
Available as an option.
The following tightening torques apply:
• Fittings:
Observe the manufacturer's specifications regarding the tightening torques of the
fittings used.
• Female threads in the axial piston unit:
The max. permissible tightening torques
M
G max
are the maximum values for the
female threads and should not be exceeded. For values, see Table 12.
• Threaded plugs:
For the metallic threaded plugs supplied with the axial piston unit, the required
tightening torques of threaded plugs
M
V
apply. For values, see Table 12.
• Mounting bolts:
For mounting bolts with metric ISO threads according to DIN 13 and/or ASME B1.1
threads, we recommend checking the tightening torque in individual cases in
accordance with VDI 2230.
Port overview