Installation 29/56
RE 91706-01-B/09.2015, A10VER Series 52,
Bosch Rexroth AG
7.3.2 Above-reservoir installation
Above-reservoir installation means that the axial piston unit is installed above the
minimum fluid level of the reservoir.
L
h
t min
SB
h
min
L
h
t min
SB
h
min
F
3
4
Fig. 7: Above-reservoir installation A10VER with installation position 3–4
l
Highest drain port
h
t min
Minimum required immersion
depth (200 mm)
F
Filling/air bleeding
h
min
Minimum required distance to
reservoir bottom (100 mm)
Port
F
is part of the external piping and must be provided by the customer to
make filling and air bleeding easier.
Table 9: Above-reservoir installation
Installation position
Air bleeding
Filling
3 (drive shaft horizontal)
–
L
4 (drive shaft horizontal)
–
L