Installation 31/56
RE 91706-01-B/09.2015, A10VER Series 52,
Bosch Rexroth AG
•
Note that you can expect certain installation positions to affect the control
device. Gravity, dead weight and case pressure can cause minor shifts in control
characteristic curves and changes in response time.
•
If a shared drain line is used for several units, make sure that the respective case
pressure is not exceeded. The shared drain line must be dimensioned to ensure
that the maximum permissible case pressure of all connected units is not exceeded
in any operating conditions, specifically on cold start. If this is not possible,
separate drain lines may have to be laid.
The installation method for the axial piston unit depends on the connecting elements
to the output side. The following descriptions explain the installation of the axial
piston unit:
•
with a coupling
•
on a gearbox
7.4.4 Installation with coupling
How to install the axial piston unit with a coupling is described in below:
nOTICE
Danger from improper handling.
Product can be damaged.
▶
Do not install the coupling hub onto the drive shaft of the axial piston unit
by striking it.
1.
Install the specified coupling half onto the drive shaft of the axial piston unit
according to the instructions of the coupling manufacturer.
The drive shaft of the axial piston unit is equipped with a female thread. Use this
female thread to pull the coupling element onto the drive shaft. The size of the
female thread can be seen in the installation drawing.
2.
Clamp the coupling hub onto the drive shaft or ensure permanent lubrication
of the drive shaft. This prevents the formation of frictional corrosion and the
associated wear.
3.
Transport the axial piston unit to the installation location.
4.
Remove dirt and foreign particles from the installation location.
5.
Install the coupling on the drive shaft of the machine/system in accordance with
the specifications provided by the coupling manufacturer.
The axial piston unit must not be tightened down until the coupling has been
correctly installed.
6.
Fix the axial piston unit at the installation location.
7.
Align the drive shaft of the axial piston unit and the drive shaft of the machine/
system so that there is no angular deviation.
8.
Make certain that no impermissible axial and radial forces act on the drive shaft.
9.
Details on the required tools and tightening torques for the mounting bolts are
available from the machine/system manufacturer.