Installation 35/56
RE 91706-01-B/09.2015, A10VER Series 52,
Bosch Rexroth AG
B
A
L
Fig. 10: Port overview A10VER, EZx control, SAE flange port (port plate 10)
Table 10: A10VM/A10VER ports Series 52
Ports
1)
p
max
[bar]
2)
Status
A
Working port (high-pressure series)
10
O
B
Working port (high-pressure series)
350
O
l
Drain port
2
O
1)
The measuring system and thread size can be taken from the installation drawing.
2)
Depending on the application, short-term pressure peaks can occur. Keep this in mind when
selecting measuring equipment and fittings.
O = Must be connected (plugged on delivery)
X = Plugged (in normal operation)
The following tightening torques apply:
•
Fittings:
Observe the manufacturer's specifications regarding the tightening torques of the
used fittings.
•
Female threads in the axial piston unit:
The maximum permissible tightening torques
M
G max
are maximum values of the
female threads and must not be exceeded. For values, see Table 11.
•
Threaded plugs:
For the metallic threaded plugs supplied with the axial piston unit, the required
tightening torques of threaded plugs
M
V
apply. For values, see Table 11.
•
Mounting bolts:
For mounting bolts with metric ISO thread according to DIN 13 or thread according
to ASME B1.1, we recommend checking the tightening torque in individual cases in
accordance with VDI 2230.
Tightening torques