38/56 Installation
Bosch Rexroth AG
, A10VER Series 52, RE 91706-01-B/09.2015
If necessary, you can change the connector orientation by turning the solenoid.
This is dependent on the connector version.
To do this, proceed as follows:
1.
Loosen the mounting nut with rubber boot (
1
) on the solenoid. To do this, turn
the mounting nut (
1
) one turn counter-clockwise.
2.
Turn the solenoid body (
2
) to the desired orientation.
3.
Retighten the mounting nut. Tightening torque of the mounting nut: 5+1 Nm.
7.5 Performing flushing cycle
In order to remove foreign particles from the system, Bosch Rexroth recommends a
flushing cycle for the entire system before the first commissioning. To avoid internal
contamination, the axial piston unit must not be included in the flushing cycle.
The flushing cycle must be performed with an additional flushing unit. Follow the
instructions of the flushing unit's manufacturer for the exact procedure during the
flushing cycle.
Changing connector
orientation
1
2