Safety instructions 13/60
RE 92770-01-B/11.2016, A10VGT Series 11,
Bosch Rexroth AG
wARnInG
Restriction of the load holding function in lifting winches!
Risk of injury or property damage!
Moving parts in high-pressure relief valves may in certain circumstances become
stuck in an undefined position due to contamination (e.g. contaminated hydraulic
fluid). This can result in restriction or loss of the load holding function in lifting
winches.
▶
Check whether the application on your machine requires additional safety
measures, in order to keep the load in a safe position.
▶
If necessary, make sure that these are properly implemented.
CAUTIOn
High noise development during operation!
Risk of hearing damage or hearing loss!
The noise emission of axial piston units depends on, among other factors,
rotational speed, working pressure and installation conditions. The sound pressure
level may rise above 70 dB (A) in certain application conditions.
▶
Always wear hearing protection when in the vicinity of the operating axial piston unit.
Hot surfaces on the axial piston unit!
Risk of burning!
▶
Allow the axial piston unit to cool down sufficiently before touching it.
▶
Wear heat-resistant protective clothing, e.g. gloves.
Improper routing of cables and lines!
Risk of stumbling and property damage. Improper routing of cables and lines
can cause a risk of stumbling as well as damage to equipment and components,
e.g. lines and connectors tearing.
▶
Always lay cables and lines in such a way that no one can trip over them, that
they do not become kinked or twisted, do not rub on edges and do not run
without adequate protection through sharp-edged ducts.
Contact with hydraulic fluid!
Risk of adverse health effects, e.g. eye injury, skin irritation, poisoning from inhalation!
▶
Avoid contact with hydraulic fluids.
▶
When working with hydraulic fluids, strictly observe the safety instructions
provided by the lubricant manufacturer.
▶
Wear your personal protective equipment (e.g. safety goggles, safety gloves,
suitable working clothes, safety shoes).
▶
Consult a doctor immediately if hydraulic fluid gets in your eyes or bloodstream,
or is swallowed.
Escaping hydraulic fluid due to machine/system leakage!
Risk of burns and risk of injury due to escaping oil jet!
▶
Depressurize the relevant machine/system component and repair the leak.
▶
Never attempt to block or seal the leak or oil jet with a cloth.