Installation 47/104
RE 92076-01-B/10.2017, A4... with HS5E pilot control valve/Series 3x,
Bosch Rexroth AG
7.4.7 Completing installation
1.
Remove any mounted transport screws.
Use a suitable tool for this to prevent damage to the sealing and functional surface.
If the sealing or functional surface is damaged, contact your Bosch Rexroth service
partner or the service department of the manufacturer's plant for the axial piston
unit.
CAUTIOn!
Operation with protective plugs!
Operating the axial piston unit with protective plugs may result in injury or damage
to the axial piston unit.
▶
Before commissioning, remove all protective plugs and replace them with
suitable, pressure-resistant, metal threaded plugs or connect the appropriate
lines.
2.
Remove the transport protection.
The axial piston unit is delivered with protective covers (
1
) and a protective
plug (
2
). They are not pressure-resistant and have to be removed prior to
connection. Use a suitable tool for this to prevent damage to the sealing and
functional surfaces. If sealing or functional surfaces are damaged, contact your
Bosch Rexroth service partner or the service department of the manufacturer's
plant for the axial piston unit.