68/104 Commissioning
Bosch Rexroth AG
, A4... with HS5E pilot control valve/Series 3x, RE 92076-01-B/10.2017
Key
V
g
Displacement per revolution [cm
3
]
Δp
Differential pressure [bar]
n
Rotational speed [rpm]
η
v
Volumetric efficiency
η
hm
Hydraulic-mechanical efficiency
η
t
Total efficiency (
η
t
=
η
v
×
η
hm
)
Fig. 22: Parameters for torque limitation
At determination of the torque limitation value, it is assumed that efficiencies are
100%.
Example:
Electric motor output of 75 kW at 1480 rpm should not be exceeded. The
pump of the NG 355 was limited mechanically to 320 cm
3
. The value for pressure
standardization was input as 350 bar.
Electric motor
T =
60,000
×
P
=
9549
×
75
= 483.9
Nm
2
π
n
1480