74/104 Commissioning
Bosch Rexroth AG
, A4... with HS5E pilot control valve/Series 3x, RE 92076-01-B/10.2017
Fig. 26: Damped oscillation
Step
Behavior/result
Measure
1
Slow response
Check the value of the dead volume (P-0-2813) and correct
it if necessary.
2
Response is still slow
Increase P-gain (P-0-2809); if necessary, reduce D component
positive (P-0-2816)
3
Response is still slow
Reduce the integration time (P-0-2806.0.4)
Fig. 27: Unstable control
Step
Behavior/result
Measure
1
Rapid but unstable
response
Check the value of the dead volume (P-0-2813) and correct
it if necessary.
2
Reduce P-gain (P-0-2809); if necessary, reduce D component
3
Increase the integration time (P-0-2806.0.4)
4
Reduce parameter for feedback derivation actual pressure
value (P-0-2812)
Pr
es
sur
e
Time
Pressure command value
Actual pr
es
sur
e v
alue
Slow control
Pr
es
sur
e
Time
Pressure command value
Actual pr
es
sur
e v
alue
“Unstable” control