Maintenance and repair 79/104
RE 92076-01-B/10.2017, A4... with HS5E pilot control valve/Series 3x,
Bosch Rexroth AG
10 Maintenance and repair
NOTICE
Inspection and maintenance work overdue!
Risk of property damage!
▶
Perform the specified inspection and maintenance work at the intervals
described in this manual.
10.1 Cleaning and care
NOTICE
Damage to seals and electrical system due to mechanical influences!
The jet of a high-pressure cleaner may damage the seals and electrical system of
the axial piston unit!
▶
Do not point the high-pressure cleaner at sensitive components, e.g. shaft seal
ring, electrical connections, and electrical components.
For cleaning and care of the axial piston unit, observe the following:
▶
Check whether all seals and plug-in connections are securely seated to ensure
that no moisture can penetrate into the axial piston unit during cleaning.
▶
Use only water and, if necessary, a mild cleaning agent to clean the axial piston
unit. Never use solvents or corrosive cleaning agents.
▶
Remove major external contamination and keep sensitive and important
components, such as solenoids, valves, displays and sensors, clean.