Troubleshooting 89/104
RE 92076-01-B/10.2017, A4... with HS5E pilot control valve/Series 3x,
Bosch Rexroth AG
14.3 Malfunction table
Table 26: Axial piston unit malfunction table
Malfunction
Possible cause
Remedy
Unusual noises
Insufficient air bleeding of the hydraulic system
Fill the axial piston unit, suction line for the
hydraulic pump and the reservoir
Completely air bleed the axial piston unit and
hydraulic system
Check correct installation position
Insufficient suction conditions, e.g. insufficient
dimensioning of the suction line, viscosity of
the hydraulic fluid too high, suction height too
high, suction pressure too low, contaminants
in the suction line, impermissible filter in the
suction line
Machine/system manufacturer: Check the
system, e.g. optimize inlet conditions, use
suitable hydraulic fluid
Fill the suction line with hydraulic fluid
Remove foreign particles from the suction line
Drive speed too high
Machine/system manufacturer: reduce drive
speed
Wrong direction of rotation
Machine/system manufacturer: Check
correct direction of rotation, see
Chapter 7.4.1 “Preparation” on page 44
Improper mounting of the axial piston unit
Check the mounting of the axial piston unit
according to the specifications of the machine/
system manufacturer (observe tightening
torques)
Improper mounting of assembled parts,
hydraulic lines or improper installation of
the coupling
Mount assembled parts according to the
information provided by the coupling or fitting
manufacturer
Valve and controller vibrations
Optimize the adjustment of the axial piston
unit and the pressure limitation in the hydraulic
system
Mechanical damage to the axial piston unit
(e.g. bearing damage)
Replace axial piston unit
Contact Bosch Rexroth Service
Increased, unusual vibration
Bearings worn
Contact Bosch Rexroth Service