38/64 Installation
Bosch Rexroth AG, A4VG Series 35, RE 92035-01-B/2019-11-25
1
2
2
4
3
Fig. 12: Removing transport protection
1
Protective covers
2
Protective plugs/threaded plugs
3
Protective covers for sensors and
connectors
4
For version with through drive,
protective cover and mounting bolts
Ports intended for connecting lines come with protective plugs and/or threaded
plugs, which serve as transport protection. Connect all ports required for
functional operation (see Table 10 "Ports A4VG series 35Series 35" on
page 41). Failure to do so could lead to malfunctions or damage. If a port is not
being used, plug it with a threaded plug since the protective plugs are not
pressure-resistant.
Setting screws are protected against unauthorized adjustment by tamper-proof
caps. Removal of the tamper-proof caps will void the warranty. If you need to
change the settings, please contact your local contact person; you can find their
contact information at
www.boschrexroth.com/addresses
3.
For versions with through drive, install the auxiliary pump according to the pump
manufacturer's instructions. The protective cover (
4
) is not pressure-resistant and
is therefore not permitted during operation.