42/64 Installation
Bosch Rexroth AG, A4VG Series 35, RE 92035-01-B/2019-11-25
Table 11: Tightening torques for female threads and threaded plugs
Ports
Maximum permissible
tightening torque of
female threads
M
G max
Required tightening torque
of threaded plugs
M
V
WAF hexagon socket of the
threaded plug
Standard
Thread size
ISO 6149
M8 × 1
10 Nm
7 Nm
4 mm
M10 × 1
30 Nm
15 Nm
5 mm
M12 × 1.5
50 Nm
25 Nm
6 mm
M14 × 1.5
80 Nm
45 Nm
6 mm
M16 × 1.5
100 Nm
55 Nm
8 mm
M18 × 1.5
140 Nm
70 Nm
8 mm
M20 × 1.5
170 Nm
80 Nm
10 mm
M22 × 1.5
210 Nm
100 Nm
10 mm
M27 × 2
330 Nm
170 Nm
12 mm
M30 × 2
420 Nm
215 Nm
17 mm
M33 × 2
540 Nm
310 Nm
17 mm
M42 × 2
720 Nm
330 Nm
22 mm
M48 × 2
900 Nm
420 Nm
22 mm
ISO 11926
5/16-24 UNF-2B
10 Nm
7 Nm
1/8 in
3/8-24 UNF-2B
20 Nm
10 Nm
5/32 in
7/16-20 UNF-2B
40 Nm
18 Nm
3/16 in
9/16-18 UNF-2B
80 Nm
35 Nm
1/4 in
3/4-16 UNF-2B
160 Nm
70 Nm
5/16 in
7/8-14 UNF-2B
240 Nm
110 Nm
3/8 in
1 1/16-12 UN-2B 360 Nm
170 Nm
9/16 in
1 5/16-12 UN-2B 540 Nm
270 Nm
5/8 in
1 5/8-12 UN-2B
960 Nm
320 Nm
3/4 in
1 7/8-12 UN-2B
1200 Nm
390 Nm
3/4 in
To connect the axial piston unit to the hydraulic system:
1.
Remove the protective plugs and/or threaded plugs from the ports where the
connections should be made according to the hydraulic circuit diagram.
2.
Make sure the sealing surfaces of the hydraulic ports and functional surfaces are
not damaged.
3.
Use only clean hydraulic lines or flush them before installation.
(Observe chapter 7.5 "Performing flushing cycle" on page 43 when you flush
the hydraulic system.)
4.
Connect the lines in accordance with the installation drawing and the machine
or system circuit diagram. Check that all ports are connected or plugged with
threaded plugs.
5.
Properly tighten the fittings (observe tightening torques!). Mark all properly
tightened fittings, e.g. with a permanent marker.
6.
Check all pipes and hose lines and every combination of connecting pieces,
couplings or connecting points with hoses or pipes to ensure they are in
safe working condition.
For relationship between direction of rotation and flow direction,
see data sheet 92035.
Procedure