60/64 Troubleshooting
Bosch Rexroth AG, A4VG Series 35, RE 92035-01-B/2019-11-25
Table 13: Axial piston unit malfunction table
Malfunction
Possible cause
Remedy
Pressure/flow fluctuations/
instabilities
Insufficient air bleeding of the hydraulic system Fill the axial piston unit, suction line for the
hydraulic pump and the reservoir
Completely air bleed the axial piston unit and
hydraulic system
Check correct installation position
Insufficient suction conditions, e.g., insufficient
dimensioning of the suction line, viscosity of
the hydraulic fluid too high, suction height
too high, suction pressure too low, foreign
particles in the suction line, suction filter
too small or blocked, etc.
Machine/system manufacturer: Check the
system, e.g. optimize inlet conditions,
use suitable hydraulic fluid
Fill the suction line with hydraulic fluid
Remove foreign particles from the suction line
Check the filter system and change the filter
as necessary
Oscillate pressure relief valves and pressure
control valves in the axial piston unit
(boost-pressure relief valve, high-pressure relief
valve, pressure reducing valve)
Air bleed the axial piston unit and hydraulic
system
Contact Bosch Rexroth Service
Unstable control signal
Contact machine/system manufacturer or
Bosch Rexroth Service
Malfunction in the control devices or the
controller
Contact Bosch Rexroth Service
Excessively high temperature of
hydraulic fluid and housing
Excessively high inlet temperature at the axial
piston unit
Machine/system manufacturer: Inspect system,
e.g. malfunction in the cooler, insufficient
hydraulic fluid in the reservoir
Wrong setting and/or malfunction of the
pressure relief and pressure control valves
(e.g. high-pressure relief valve, pressure
controller, pressure reducing valve)
Optimize the adjustment of the pressure
limitation and pressure control valves of the
axial piston unit and the pressure safeguarding
in the hydraulic system
Contact Bosch Rexroth Service
Contact machine/system manufacturer
Flushing flow of the flushing valve too low
Contact Bosch Rexroth Service
Axial piston unit worn
Replace axial piston unit; contact
Bosch Rexroth Service