28/68
Transport and storage
Bosch Rexroth AG
, A4VG Series 40, RE 92004-01-B/05.2017
A dismounted axial piston unit must be preserved with corrosion protection for the
duration of storage.
The following instructions only refer to axial piston units which are operated
with a mineral oil-based hydraulic fluid. Other hydraulic fluids require
preservation measures that are specifically designed for them. In such a case,
consult with your local contact person, you can find the address under
www.boschrexroth.com/addresses
Bosch Rexroth recommends the following procedure:
1.
Clean the axial piston unit, see chapter 10.1 “Cleaning and care” on page 51.
2.
Empty the axial piston unit.
3.
For storage times up to 12 months: Coat the inside of the axial piston unit with
mineral oil and fill with about 100 ml mineral oil.
For storage times up to 24 months: Fill the axial piston unit with corrosion
protection VCI 329 (20 ml).
Filling is done through the drain port
T
1
or
T
2
, see chapter 7.4 “Installing the axial
piston unit”, Fig. 13 to Fig. 14 on page 41.
4.
Plug all ports so they are airproof.
5.
Moisten the unpainted areas of the axial piston unit with mineral oil or suitable,
easily removable corrosion protection, e.g. acid-free grease.
6.
Package the axial piston unit with desiccant in corrosion protection film so it is
airproof.
7.
Store the axial piston unit in a shock-proof manner, see “Requirements” on page
27 in this chapter.
After removal