Bosch Rexroth AG
, RE 92202/02.2015
20
A7VO Series 63
| Axial piston variable pump
EP – Proportional electric control
EP – Proportional electric control
The proportional electric control, type EP, provides continu-
ous control of the displacement. Control is proportional to
the electric control current applied to the solenoid.
▶ Control from
V
g min
to
V
g max
(positive control)
As the pilot pressure increases, the pump swivels to a
larger displacement.
A control pressure of 40 bar is needed to swivel the pump
from its initial position
V
g min
to
V
g max
.
The necessary control power is taken from the operating
pressure or the external control pressure applied to port
Y
3
.
To ensure that control is guaranteed at a low operating
pressure of < 40 bar too, port
Y
3
must be supplied with an
external control pressure of about 40 bar.
Various BODAS controllers with application software and
amplifiers are available for controlling the proportional
solenoids.
Further information can also be found on the Internet at
www.boschrexroth.com/mobile-electronics.
Technical data, solenoid
EP2
Voltage
24 V (±20%)
Control current
Start of control
200 mA
End of control
600 mA
Current limit
0.77 A
Nominal resistance (at 20 °C)
22.7 Ω
Dither frequency
100 Hz
Duty cycle
100%
Type of protection: see connector version page 40
▼ Characteristic curve EP2 positive control
0
0.6
0.8
1.0
0.4
0.2
800
700
600
500
400
300
200
100
Displacement
V
g
/
V
g max
Contr
ol cur
rent
I
[mA]
▼ Schematic EP2
R
2
U
R
1
V
g min
V
g max
T
1
X
3
Y
3
B(A)
A
1
M
1
S