stress the connection thread at the housing to an unreasonably high extent
and/or damage it permanently.
The machine manufacturer is responsible for ensuring that the
coolant connection is tight and for verifying and accepting the
tightness after the energy storage device has been installed.
Additional, regular inspections to ensure proper condition of the
coolant connection should be logged in the maintenance sched‐
ule of the machine.
8.6.3
Coolant input pressure
The maximum coolant input pressure of 6 bar applies to all BA1N energy
storage devices based on the effective current pressure directly at the cool‐
ant connection on the energy storage device.
Please observe that additional screw connections or junctions in the cooling
circuit can have a negative influence on the flow and supply pressure of the
cooling medium.
BA1N Kinetic Energy Buffer
33/73
Connection technique
R911393264_Edition 01 Bosch Rexroth AG
Summary of Contents for Rexroth BA1N
Page 1: ...BA1N Kinetic Energy Buffer Project Planning Manual R911393264 Edition 01 ...
Page 30: ...24 73 BA1N Kinetic Energy Buffer Bosch Rexroth AG R911393264_Edition 01 ...
Page 32: ...26 73 BA1N Kinetic Energy Buffer Bosch Rexroth AG R911393264_Edition 01 ...
Page 40: ...34 73 BA1N Kinetic Energy Buffer Bosch Rexroth AG R911393264_Edition 01 ...
Page 52: ...46 73 BA1N Kinetic Energy Buffer Bosch Rexroth AG R911393264_Edition 01 ...
Page 62: ...56 73 BA1N Kinetic Energy Buffer Bosch Rexroth AG R911393264_Edition 01 ...
Page 74: ...68 73 BA1N Kinetic Energy Buffer Bosch Rexroth AG R911393264_Edition 01 ...
Page 77: ...Notes BA1N Kinetic Energy Buffer 71 73 ...
Page 78: ...Notes 72 73 BA1N Kinetic Energy Buffer ...