Fig.4-34:
USB interface
PIN
Designation
1
USB power supply (max. 500 mA)
2
Data -
3
Data +
4
USB ground
Fig.4-35:
Pin assignment of the USB interface
4.7.3
LPT1 Printer Interface and SIS
General Information
The serial interface COM2 (X16) is switched according to the Rexroth standard
(SIS). The LPT1 printer interface features the default Centronics assignment.
Both interfaces are explained more detailed in the following.
LPT1 interface
Fig.4-36:
LPT1 interface
PIN
Signal designation
PIN
Signal designation
1
/STB - Strobe
2
PD0
3
PD1
4
PD2
5
PD3
6
PD4
7
PD5
8
PD6
9
PD7
10
/ACK - Acknowledge
11
Busy
12
PE - Paper End
13
SLCT - Select
14
/AFD - Auto Feed
15
/ERR - Error
16
/INIT
17
/SLCTIN - Select In
18
GND
19
GND
20
GND
21
GND
22
GND
23
GND
24
GND
25
GND
Fig.4-37:
Pin assignment of the LPT1 interface
Project Planning Manual | Rexroth MTA 200
Electric Drives
and Controls
| Bosch Rexroth AG
47/135
Machine Operator Terminal BTV 20.4A
Summary of Contents for Rexroth BTV 20.4A
Page 12: ...10 135 Bosch Rexroth AG Electric Drives and Controls Rexroth MTA 200 Project Planning Manual ...
Page 66: ...64 135 Bosch Rexroth AG Electric Drives and Controls Rexroth MTA 200 Project Planning Manual ...
Page 134: ...132 135 Bosch Rexroth AG Electric Drives and Controls Rexroth MTA 200 Project Planning Manual ...