![background image](http://html.mh-extra.com/html/bosch/rexroth-efc-3600/rexroth-efc-3600_operating-instructions-manual_40573199.webp)
Function
code
Name
Setting range
Min.
unit
Factory
default
Attribute
b0.22
Automatic
adjustment of
carrier frequency
0: OFF
1: ON
1
0
STOP
b0.23
~
b0.29
Reserved
–
–
–
–
Monitoring display
Function
code
Name
Setting range
Min.
unit
Factory
default Attribute
b0.30
Running
monitoring
display
0: Output frequency
1: Output rotation speed
2: Set frequency
3: Set rotation speed
4: Output voltage
5: Output current
6: Output power
7: DC bus voltage
8: Analog input AIV
9: Analog input AIC
10: User-defined set frequency
11: User-defined output fre‐
quency
12: Digital input status
13: Digital output status
14: PID target engineer value
15: PID feedback engineer val‐
ue
16: Module temperature
17: Firmware version 1
18: Firmware version 2
19: Firmware version 3
20: Actual carrier frequency
1
0
RUN/
STOP
b0.31
Stop
monitoring
display
1
2
RUN/
STOP
DOK-RCON03-EFC-3600***-IT01-EN-P
Rexroth Frequency Converter EFC 3600
Bosch Rexroth AG
Appendix
197/235
Summary of Contents for Rexroth EFC 3600
Page 6: ...Bosch Rexroth AG DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 IV 235 ...
Page 232: ...230 235 ...
Page 236: ...Bosch Rexroth AG DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 234 235 ...
Page 237: ...Notes DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 Bosch Rexroth AG ...