7.2
Commissioning Process
Step
Operation
Description
1
Rotate the potentiometer counterclock‐
wise (leftwards) to the greatest extent
The initial frequency value is 0.00
2
Press Run key
Enter the command for running, with
0.00 displayed
3
Rotate the potentiometer clockwise
(rightwards) slowly and the displayed
value starts to change, until 5.00 is dis‐
played
The motor starts to run
4
Observe:
● Whether the motor runs in the correct
direction
● Whether the motor runs smoothly
● Whether there is any abnormal noise
or problem
Observe the running, and immediately
stop the motor by shutting off the pow‐
er if any abnormality occurs. Restart
commissioning only after the fault
causes have been removed
5
Rotate the potentiometer clockwise
(rightwards)
The motor accelerates
6
Rotate the potentiometer counterclock‐
wise (leftwards)
The motor decelerates
7
Press Stop key
When commissioning is complete, the
command for stopping is activated.
The frequency converter is ready for
normal operation.
Fig.7-1: Commissioning process
Bosch Rexroth AG
Commissioning
DOK-RCON03-EFC-3600***-IT01-EN-P
Rexroth Frequency Converter EFC 3600
48/235
Summary of Contents for Rexroth EFC 3600
Page 6: ...Bosch Rexroth AG DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 IV 235 ...
Page 232: ...230 235 ...
Page 236: ...Bosch Rexroth AG DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 234 235 ...
Page 237: ...Notes DOK RCON03 EFC 3600 IT01 EN P Rexroth Frequency Converter EFC 3600 Bosch Rexroth AG ...