20/72
Transport and storage
Bosch Rexroth AB
, RE 15300-WA, Version 06.2021
Fig. 13: Filling the motor with oil
6.2.2 Storing for extended periods or in uncontrolled environment
NOTICE
Insufficient cleanliness!
Risk of damage to equipment.
▶ Take extreme care to ensure that no contamination enters inside the motor.
If the motor is stored for more than 3 months in uncontrolled environment or more
than 12 months in controlled environment, it must be filled full with oil according
to below:
1.
Place the motor as shown in
, alt.A) Standing with shaft horizontal.
2.
Fill the motor full with filtered oil containing a mixture of 0,4% FUCHS
ANTICORIT VCI UNI O 40, or similar corrosion inhibitor compatible with the
selected fluid in the following order: D1, A1 and C1.
NOTE!
See
for oil volume
3.
Fit the plug to D1.
4.
Seal connections A1 and C1 with the cover plates fitted to the connection
surfaces at delivery. Check that the O-rings or rubber seals are in position in
the cover plates.
5.
Position the motor as shown in
, alt. A) Standing with shaft horizontal or
B) Standing with shaft vertical.
A1
C1
D1
Cover plate
DD00058244
Table 6: Motor case oil volume
Motor size
Motor case oil volume including channels
Litre
US gallon
CBm 2000
75
19.8
CBm 3000
91
24.0
CBm 4000
107
28.2
CBm 5000
123
32.4
CBm 6000
138
36.4