R911323106
/
02
|
Rexroth IndraControl VCP 35.2
Electric Drives and Controls |
Bosch Rexroth AG
4
-3
Technical Data
4.4
Interfaces
4.5
Central Processing Unit and Memory
Ethernet
X5 Ethernet
10/100 Base-T
Serial Interfaces
Variable Baud Rates and Data Formats
X6 SER1 RS485
In Accordance With DIN 66259-4
Transmission Length: 0 - 1200 m (up to 3937 feet),
Twisted Pair Wire, Shielded
Galvanically Isolated
X6 SER1 RS232 / X6 SER2 RS232
In Accordance With DIN 66259 T1, CCITT V.28
Transmission Length: 0 - 15 m (up to 49.212 feet), Con-
ductors Layered in Strands, Shielded X6 SER1: Galvan-
ically Isolated
X6 SER2: Galvanically Not Isolated
Field Bus Interfaces
Variable Baud Rates and Data Formats
X6 PROFIBUS DP
Galvanically Isolated
USB
Corresponds to the "Universal Serial Bus Specification Rev. 2.0“
X9, X10 Host
Min.: 1.5 Mbit/s
Max.: 12 Mbit/s
Max. Output Current 100 mA per Output
Central Processing Unit
Central Processing Unit
RISC ARM9
Clock Frequency
200 MHz
Other Features
Watchdog Timer, Real-Time Clock, Battery Monitoring
Summary of Contents for Rexroth IndraControl VCP 35.2