10.2 Installation notes
●
Provide a space of 50 mm on all sides for sufficient cooling and cable routing.
●
The LED display on the operator panel must not be covered.
●
Wire all cables in loops. Use strain reliefs for all cables.
●
Install the operator display only vertically, with a max. deviation of ±45°,
measured from the vertical.
●
Do not lay the CDI cables in parallel to motor cables or to other noise sour-
ces, as the CDI connection can be disturbed. Keep the maximum distance
possible from interference sources.
10.3 Mounting
To mount the operator display, proceed as follows: