Errors
Troubleshooting
No image visible
●
Connect the supply voltage and check the X1S1 connec-
tion
●
Connect the CDI cable correctly and check XVID and
XSER
●
Set the image output in the graphics driver to "VDP"
●
Switch on the voltage at the operator display before or
with the control cabinet PC
Distorted display due to incorrect dis-
play resolution
●
Set the correct display resolution in the graphics driver
●
Restart the control cabinet PC
The USB flash drive does not work, al-
though other USB devices work
●
Set the DIP switch on the VDP to <30 m
●
Note: USB memory sticks can only be used up to a cable
length of 30 meters
USB devices and touch screen do not
work
●
Set the DIP switch appropriately to the cable length
Limited operability of the operator dis-
play
●
Avoid strong high-frequency interferences close to the
operator display
Tab. 13-1: Error causes and troubleshooting
Repairs at the device by the customer are not permitted. Exceptions
are maintenance works listed in the chapter "Maintenance".
For further information in the event of repair, please contact the
Bosch Rexroth Service.
14 Maintenance
Loss of IP degree of protection due to incorrect
maintenance.
NOTICE
Ensure that the IP degree of protection remains during maintenance!
Only the maintenance works at the device listed in this chapter are
permitted.
For further information in the event of repair, please contact the
Bosch Rexroth Service.
14.1 Display
The backlight is subject to wear, see
chapter 5.6 "Wear parts" on page 8
Bosch Rexroth AG
Maintenance
30/37
DOK-SUPPL*-VDPXX.3MTBU-IT03-EN-P