14.2 Cleaning notes
Dissolving front glass sealing with solvent and
high-pressure cleaning devices!
NOTICE
●
Do not use solvents.
●
Do not use high pressure cleaning devices.
14.3 Scheduled maintenance tasks
●
Check all plug and terminal connections of the components for proper tight-
ness and possible damage at least annually.
●
Check that cables are not broken or crushed.
●
Replace damaged parts immediately.
14.4 battery
The VEP xx.6 devices are provided with a lithium battery CR1632 to buffer the
real-time clock. If this battery is empty or weak, the clock setting is lost in the
BIOS.
Replace the battery every five years.
Batteries can cause fire, explosions or chemical
burn.
WARNING
Do not load, remove, destroy, burn or heat batteries over 100 °C. Dispose old
batteries immediately and properly. Keep away from children!
Use only the battery specified in
chapter 5.2 "Lithium battery" on
by Bosch Rexroth.
14.4.1 Exchanging the battery
At the housing device, the battery is located under the cover on the rear side of
the device.
1. Do not switch off the device to avoid loss of data while exchanging the bat-
tery.
2. Remove the screws of the cover on the rear side and then remove the cov-
er.
3. Remove the old battery and connect the new battery. Ensure that the bat-
tery plugs are correctly engaged.
4.
IndraControl VEP 30.6, VEP 40.6,
VEP 50.6 Embedded Terminals
39/49
Maintenance
R911403058_Edition 01 Bosch Rexroth AG