LED
Color
Function
U
L
Green
24 V supply voltage connected and within the permitted range
ON
Green
All internally programmable function blocks are loaded. These also in-
clude internally programmed function blocks of connected modules.
ON
Red
Loading for internally programmable functions block of an extension
module or of the control failed. In this case, initiate a fallback. Refer to
chapter 12.5 "Fallback and recovery" on page 54
T
Red
●
The temperature is critical.
●
If the control cannot be operated anymore, the maximum tempera-
ture was exceeded and the control was switched off. The control
can only be operated when interrupting the voltage.
The messages "Prewarning" and "Shutdown" are displayed at a high
operating temperature together with the diagnostic display of the en-
gineering interface. A temperature display is shown additionally. The
sensor for all these messages is located at a selected position in the
power supply area. The temperature display is only for visual represen-
tation purposes. It displays neither the ambient temperature nor the
indoor temperature of the XM2.
Tab. 12-1: LED functions on the XD1 plug
12.1.2 LED block of 10
Stop
Run
Clear
IndraControl XM21
24V 0V
SD
Ethernet sercos
R
ese
t
Pr
og
XF1
XF5
SF2
XF31
XG10
SF1
XD1
XF30
XF2
STA
ERR
BT
D
E
s
DIA1
S L
L
S
S L
DIA2
DIA3
DIA4
ON
UL T
USV 0V
STA
BT
D
E
s
DIA1
DIA2
DIA3
DIA4
ERR
Fig. 12-3: LED block of 10
36/69
Device description
IndraControl XM21, XM22 Controls
Bosch Rexroth AG R911340667_Edition 04
Summary of Contents for Rexroth IndraControl XM21
Page 1: ...IndraControl XM21 XM22 Controls Operating Instructions R911340667 Edition 04 ...
Page 6: ...IV IndraControl XM21 XM22 Controls Bosch Rexroth AG R911340667_Edition 04 ...
Page 70: ...64 69 IndraControl XM21 XM22 Controls Bosch Rexroth AG R911340667_Edition 04 ...
Page 73: ...IndraControl XM21 XM22 Controls 67 69 R911340667_Edition 04 Bosch Rexroth AG ...
Page 74: ...68 69 IndraControl XM21 XM22 Controls Bosch Rexroth AG R911340667_Edition 04 ...