Overview of standards applying as test methods and measuring methods in accordance with the product standard EN
61800-3 for adjustable speed electrical power drive systems:
Noise emission
Conducted emission (interference voltage)
EN 55011
A 1 or C2
B 1 or C1
Radiated emission (interference-field strength)
EN 55011
A 1 or C2
-
Noise immunity EN 61000-6-1, EN 61000-6-2
ESD, discharge of static electricity
EN 61000-4-2
6kV (CD), 8kV (AD)
EMF, high-frequency electromagnetic fields
EN 61000-4-3
10 V/m; 80 - 1000 MHz
Burst on control lines
EN 61000-4-4
1 kV
Burst on mains lines and motor lines
EN 61000-4-4
2 kV
Surge (phase-phase / ground)
EN 61000-4-5
1 kV / 2 kV
Conducted disturbance by high-frequency fields
EN 61000-4-6
10 V, 0.15 - 80 MHz
Voltage fluctuations and voltage dips
EN 61000-2-1
+10%, -15%; 90%
Voltage asymmetries and frequency changes
EN 61000-2-4
3%; 2%
Fig.5-1:
Noise Immunity
5.1.4
Wiring Recommendations for Power Connections
Connect the cable shield on both sides, i.e. at the shield angle of
the frequency converter housing and at the motor terminal box.
Fig.5-2:
Wiring
DOK-INDRV*-FCS01******-IT01-EN-P
Rexroth IndraDrive Fc Drive Controllers Frequency Converters FCS01
Bosch Rexroth AG
35/69
Instructions for Use
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01