Rexroth IndraDrive
Electrical Installation
7-19
DOK-INDRV*-HMV-*******-PR01-EN-P
PE Connection of Power Supply
HMV01.1E-W0030, -W0075
HMV01.1R-W0018, -W0045, -W0065
HMV01.1E-W0120
hmv_erdanschluss_netz_30.fh7
hmv_erdanschluss_netz_120.fh7
Abb. 7-13: PE connection of power supply
The ground wire is fixed to the supply unit with screws:
HMV01.1E-W0030, -W0075
HMV01.1R-W0018, -W0045, -W0065
HMV01.1E-W0120
M6 x 25
M10
HMV01.1E-W0030, -W0075
HMV01.1R-W0018, -W0045, -W0065
HMV01.1E-W0120
6 Nm
18 Nm