Rexroth IndraDrive
Electrical Installation
7-31
DOK-INDRV*-HMV-*******-PR01-EN-P
7.6 Touch
Guard
WARNING
Lethal electric shock caused by live parts with
more than 50 V!
⇒
The appropriate touch guard must be mounted for
each supply unit following connection work.
⇒
Never mount a damaged touch guard.
⇒
Immediately replace a damaged touch guard by an
undamaged touch guard.
Cutouts
hms_beruehrschutz_seite.fh7
A
B
C
Fig. 7-40:
Cutouts at the touch guard
WARNING
Lethal electric shock caused by live parts with
more than 50 V!
⇒
You have to provide the best possible protection
against contact. Therefore keep the cutouts at the
touch guard as small as possible.
⇒
Only break off the cutouts if necessary.
•
If the DC bus and the control voltage are connected by means of
contact rails, only the cutout C (see picture) may be broken off the
touch guard.
•
If the DC bus and the control voltage are connected by means of
cables (e.g. in the case of multiple-line arrangement of the drive
controllers), the cutouts A, B and C (see picture) may be broken off
the touch guard.
Summary of Contents for Rexroth IndraDrive HMV01.1E-W0030
Page 30: ...5 2 Transport and Storage Rexroth IndraDrive DOK INDRV HMV PR01 EN P Notes ...
Page 40: ...6 10 Mechanical Mounting Rexroth IndraDrive DOK INDRV HMV PR01 EN P Notes ...
Page 88: ...9 8 Control Mains Contactor Rexroth IndraDrive DOK INDRV HMV PR01 EN P Notes ...
Page 122: ...13 22 Appendix Rexroth IndraDrive DOK INDRV HMV PR01 EN P Fig 13 25 HFD01 2 480 0026 ...
Page 123: ...Rexroth IndraDrive Appendix 13 23 DOK INDRV HMV PR01 EN P Fig 13 26 HFD02 2 480 0026 ...
Page 130: ...14 6 Index Rexroth IndraDrive DOK INDRV HMV PR01 EN P Notes ...
Page 131: ......