4.5
Connection
High electrical voltage! Danger to life by elec‐
tric shock!
WARNING
Do not remove connectors when the component has been powered. Do not
plug in connectors when the component has been powered.
Wait at least 30 minutes after switching off the supply voltages to allow dis‐
charging.
4.5.1
Connection points
Figure
Element Significance
X37
X38
Digital inputs/outputs
X103.1
X103.2
Hybrid cable
X118
X119
External communication
X141
-
XD1
1)
Mains voltage
XD10 Control voltage
XD13
3)
KMV03.1R-Wxxxx:
Fan
XG3
2)
Mains choke temperature
contact
XG14
2)
Mains voltage synchroniza‐
tion
XG34
1)
Mains contactor control and
feedback contacts (KNK03)
Second connection point of
equipment grounding con‐
ductor
1)
RKH0800 cable connects KMV to KNK
2)
RKH0801 cable connects KMV to KNK
3)
RKB0054 cable
Tab. 4-2:
KMV03 connection points
IndraDrive Mi KMV03 Distributed Supply Unit KNK03 Distrib‐
uted Mains Filter
19/29
Instructions for use
R911374765_Edition 01 Bosch Rexroth AG