Figure
Element Significance
XD1
Mains voltage supply input
1)
XD1.2
2)
Output to load KMV03 (XD1,
mains voltage)
1)
XD13
4)
KNK03.1A-NR-Wxxxx:
Fan
XG14
3)
Output to load KMV03
(XG14, mains voltage syn‐
chronization)
XG3
3)
Mains choke temperature
contact
XG34
2)
Mains contactor control and
feedback contacts
Second connection point of
equipment grounding con‐
ductor
1)
Coding pins prevent the connectors XD1 and XD1.2 from being
incorrectly plugged
2)
RKH0800 cable connects KMV to KNK
3)
RKH0801 cable connects KMV to KNK
4)
RKB0054 cable
Tab. 4-3:
KNK03 connection points
Connection point
Cable
X37, X38
RKS0010
X103.1, X103.2
RKH0xxx
1)
X1x8, X1x9
RKB0043, RKB0044
XD1 (KNK03)
Customer assembles the cable (HAS05.1-019 accessories re‐
quired)
XD1 (KMV03),
XD1.2 (KNK03)
RKH0800
XG34
XG3
RKH0801
XG14
XD10
Customer assembles the cable (HAS05.1-020 accessories re‐
quired)
XD13
RKB0054
1)
Ready-made hybrid cable depending on the desired outgoing
directions of the hybrid cable at the connection points X103.1
and X103.2
Tab. 4-4:
Cable
20/29
Instructions for use
IndraDrive Mi KMV03 Distributed Supply Unit KNK03 Distrib‐
uted Mains Filter
Bosch Rexroth AG R911374765_Edition 01