Description
Symbol
Unit
Value
Derating vs. installation altitude:
Applies to the following devices:
● XCS1-W0xxx
● XMD1-W7070, -5454
At an installation altitude h > h
nenn
, the
available performance data are reduced by the
factor f
1)
.
Use above h
max
is not allowed!
h
max
m
4000
Derating vs. installation altitude:
Applies to the following devices:
● XMD1-W2323, -1616, -1010, -0606
● XMQ1-WQ001, -WQ002
At an installation altitude h > h
nenn
, the
available performance data are reduced by the
factor f
1)
.
At an installation altitude in the range
h
max_ohne
to h
max
, an isolating transformer has
to be installed at the drive system mains
connection.
Use above h
max
is not allowed!
h
max_ohne
m
2000
h
max
m
4000
Simultaneous derating for ambient
temperature [°C] and installation altitude [m]
Allowed;
reduce performance data with the product f × F
Ta
Derating factors (for f
Ta
= 2 %/K)
[°C]
[m]
1000
2000
4000
25
1
1
0.82
30
1
0.96
0.76
35
1
0.88
0.69
40
1
0.8
0.62
45
0.9
0.72
0.57
50
0.8
0.64
0.5
55
0.7
0.56
0.44
Relative humidity
%
5 … 95
Absolute humidity
g/m
3
1 … 29
Moisture condensation
Not allowed
Climatic category (IEC 60731‑3‑3)
3K3
Allowed pollution degree (IEC 60664‑1)
2
Resistance to chemically active substances
Class 3C1
28/123
Ambient conditions
IndraDrive X Drive Controllers Power Sections XCS1, XMD1,
XMQ1