Description
Symbol
Unit
Value
Vibration sine: amplitude (peak-peak) at
10 … 57 Hz
mm
0.15
Vibration sine: acceleration at 57 … 150 Hz
g
1
Overvoltage category
III (according to IEC 60664-1)
1)
Reduced performance data for drive controllers: allowed DC
bus continuous power, braking resistor continuous power, con‐
tinuous current; additionally for converters: allowed mains volt‐
age
Tab. 6-1:
Ambient and operating conditions
6.1
Transporting the components
Ambient and operating conditions - transport
Description
Symbol
Unit
Value
Temperature range
T
a_tran
°C
-25 … +70
Relative humidity
%
5 … 95
Absolute humidity
g/m
3
1 … 60
Climatic category (IEC721)
2K3
Moisture condensation
Not allowed
Icing
Not allowed
Tab. 6-2:
Ambient and operating conditions - transport
6.2
Storing the components
Risk of damage to components from long-
term storage!
NOTICE
Some components contain electrolytic capacitors which may deteriorate
during storage.
When storing the following components for a longer period of time, run them
once a year for at least 1 hour:
●
Converters and supply units: Operated with mains voltage U
LN
●
Inverters and DC bus capacitor units: Operated with DC bus voltage
U
DC
Ambient and operating conditions - storage
Description
Symbol
Unit
Value
Temperature range
T
a_store
°C
-25 … +55
Relative humidity
%
5 … 95
Absolute humidity
g/m
3
1 … 29
Climatic category (IEC721)
1K3
IndraDrive X Drive Controllers Power Sections XCS1, XMD1,
XMQ1
29/123
Ambient conditions
R911392532_Edition 01 Bosch Rexroth AG